Input power supply | 3 phase 380V to 480V ±10%, 50/60Hz ±5% |
Converter type | 24 pulse diode front end |
Inverter type | IGBTs |
Input current protection | Circuit breaker |
Input surge suppression | IEC test classification / EN type: II/T2 |
Maximum continuous voltage: 350V(L-PE) | |
ISCCR: 50kA (max.200A gG) | |
Voltage protection level: 1500V | |
In: 20kA 8/20 μs | |
Imax: 40kA 8/20 μs | |
Input power balance | Standard input DC reactors |
Output voltage | The same as power supply |
Output frequency | 0.1Hz to 120Hz |
Output waveform | High performance Sinewave |
Motor control | Constant or Variable Torque (V/F) |
Motor technology | Induction motor (IM) or Permanent Magnet Motor (PMM) |
Efficiency | ~96% at full load |
Power factor | 0.98 across entire speed range |
Overload rating | 120% for 1min/5min |
Certifications | ISO90001 ISO14001 |
Enclosure rating | Junction box & main power section: IP66 [ equivalent to NEMA4 ] |
24 pulse front end section:IP55 [ equivalent to NEMA3 ] | |
Magnetics section: IP24 [ equivalent to NEMA3R ] | |
Backpack section: IP24 [ equivalent to NEMA3R ] | |
Cooling system | IP66: air-conditioning unit, heat sink |
IP24 & IP55 : forced air cooling | |
Altitude | 0 to 1000m without derating |
Ambient operating temperature | -30 ℃ to 55 ℃ |
Relative humidity | 20% to 95% maximum(noncondensing) |
H2S protection | Conformal-coated PCBs & bus bars |
Material | Carbon steel, the thickness is 2.5mm |
Line-side termination | Lugs in power junction box |
Load-side termination | Lugs in power junction box |
Control termination | Mounting plate on the dedicated swing door |
Safety features | Emergency stop button |
Electronic interlocks | |
Separated power and control sections | |
Backspin indication LED on the front door | |
Prewired IO junction box | |
Analog inputs (AI) | Qty 2: 4-20mA, resolution 12 bits |
Digital inputs (DI) | Qty 5: DC24V, sink wiring |
Digital outputs (DO) | Qty 4: relay output, NO, up to 5A |
Serial communication | Qty 1: RS485 Modbus Master (for DHS) |
Qty 1: RS485 Modbus Slave (for SCADA) |