| Input power supply | 3 phase 380V to 480V ±10%, 50/60Hz ±5% |
| Converter type | 6 pulse diode |
| Inverter type | IGBTs |
| Input current protection | Circuit breaker |
| Input surge suppression | IEC test classification / EN type: II/T2 |
| Maximum continuous voltage: 350V(L-PE) |
| ISCCR: 50kA (max.200A gG) |
| Voltage protection level: 1500V |
| In: 20kA 8/20 μs |
| Imax: 40kA 8/20 μs |
| Input low harmonic | Integrated passive harmonic filter |
| Output voltage | The same as power supply |
| Output frequency | 0.1Hz to 120Hz |
| Output waveform | High performance Sinewave |
| Motor control | Constant or Variable Torque (V/F) |
| Motor technology | Induction motor (IM) or Permanent Magnet Motor (PMM) |
| Efficiency | ~96.5% at full load |
| Power factor | 0.98 across entire speed range |
| Overload rating | 120% for 1min/5min |
| Certifications | ISO9001, ISO14001 |
| Enclosure rating | Junction box & main power section: IP66 [ equivalent to
NEMA4 ] |
| Magnetics section: IP24 [ equivalent to NEMA3R ] |
| Backpack section: IP24 [ equivalent to NEMA3R ] |
| Cooling system | IP66: air-conditioning unit, heat sink |
| IP24 : forced air cooling |
| Altitude | 0 to 1000m without derating |
| Ambient operating temperature | -30 ℃ to 55 ℃ |
| Relative humidity | 20% to 95% maximum(noncondensing) |
| H2S protection | Conformal-coated PCBs & bus bars |
| Material | Carbon steel, the thickness is 2.5mm |
| Line-side termination | Circuit breaker’s lugs in power junction box |
| Load-side termination | Lugs in power junction box |
| Control termination | Mounting plate on the dedicated swing door |
| Safety features | Emergency stop button |
| Electronic interlocks |
| Separated power and control sections |
| Backspin indication LED on the front door |
| Prewired IO junction box |
| Analog inputs (AI) | Qty 2: 4-20mA, resolution 12 bits |
| Digital inputs (DI) | Qty 5: DC24V, sink wiring |
| Digital outputs (DO) | Qty 4: relay output, NO, up to 5A |
| Serial communication | Qty 1: RS485 Modbus Master (for DHS) |
| Qty 1: RS485 Modbus Slave (for SCADA) |